|
scanalytics inc
digital imaging and analysis systems zero-dscan software Digital Imaging And Analysis Systems Zero Dscan Software, supplied by scanalytics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pmc01698261-48-10-17?v=scanalytics+inc Average 90 stars, based on 1 article reviews
digital imaging and analysis systems zero-dscan software - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Hamamatsu
digital image analysis system aquacosmos Digital Image Analysis System Aquacosmos, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pmc06757629-54-2-7?v=Hamamatsu Average 90 stars, based on 1 article reviews
digital image analysis system aquacosmos - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
KEYENCE
digital vision system image analysis cv-x102 Digital Vision System Image Analysis Cv X102, supplied by KEYENCE, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pmc06681268-149-12-17?v=KEYENCE Average 90 stars, based on 1 article reviews
digital vision system image analysis cv-x102 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Vilber Lourmat
digital image analysis system bio-gene v.99 Digital Image Analysis System Bio Gene V.99, supplied by Vilber Lourmat, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/10__2225_slash_vol12___issue2___fulltext___6-42-22-26?v=Vilber+Lourmat Average 90 stars, based on 1 article reviews
digital image analysis system bio-gene v.99 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
FUJIFILM
fla-5000 fujifilm imager Fla 5000 Fujifilm Imager, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pmc07419016-227-7-8?v=FUJIFILM Average 90 stars, based on 1 article reviews
fla-5000 fujifilm imager - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
INTERFOCUS IMAGING LTD
high-precision densitometry digital image analysis system High Precision Densitometry Digital Image Analysis System, supplied by INTERFOCUS IMAGING LTD, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pm38679144-100-6-13?v=INTERFOCUS+IMAGING+LTD Average 90 stars, based on 1 article reviews
high-precision densitometry digital image analysis system - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Soft Imaging System GmbH
xt pro v3.2 Xt Pro V3.2, supplied by Soft Imaging System GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pm35929265-66-15-22?v=Soft+Imaging+System+GmbH Average 90 stars, based on 1 article reviews
xt pro v3.2 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
VISITRON Inc
digital image analysis system spot advanced software version 3.5.2 Digital Image Analysis System Spot Advanced Software Version 3.5.2, supplied by VISITRON Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pm16371592-85-5-14?v=VISITRON+Inc Average 90 stars, based on 1 article reviews
digital image analysis system spot advanced software version 3.5.2 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Tricholog GmbH
trichoscan software ![]() Trichoscan Software, supplied by Tricholog GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pmc03002414-71-7-14?v=Tricholog+GmbH Average 90 stars, based on 1 article reviews
trichoscan software - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Verlag GmbH
remote sensing digital image analysis: an introduction ![]() Remote Sensing Digital Image Analysis: An Introduction, supplied by Verlag GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/10__1088_slash_1742___6596_slash_1368_slash_3_slash_032030-82-19-20?v=Verlag+GmbH Average 90 stars, based on 1 article reviews
remote sensing digital image analysis: an introduction - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
OsteoMetrics inc
computer-assisted image analyzer osteomeasure ![]() Computer Assisted Image Analyzer Osteomeasure, supplied by OsteoMetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/pm12697707-47-12-16?v=OsteoMetrics+inc Average 90 stars, based on 1 article reviews
computer-assisted image analyzer osteomeasure - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Vilber Lourmat
digital camera and image analysis system ![]() Digital Camera And Image Analysis System, supplied by Vilber Lourmat, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/digital+image+analysis+system/10__3390_slash_i7070204-108-12-18?v=Vilber+Lourmat Average 90 stars, based on 1 article reviews
digital camera and image analysis system - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: International Journal of Trichology
Article Title: Automated Digital Image Analysis (TrichoScan®) for Human Hair Growth Analysis: Ease versus Errors
doi: 10.4103/0974-7753.66905
Figure Lengend Snippet: TrichoScan sample picture from TrichoScan manual explaining the detection and color-coding of hair strands. (a) Day 3 image; (b) TrichoScan analysis of the image in . If the hair strand is <0.7 mm in , it will be classified as telogen and coded as red in (blue circle). If the hair strand is >0.7 mm in , it will be classified as anagen and coded as green in (purple oval). Hair strands at the periphery of the analyzed image are coded as yellow (pink rounded rectangle). Moreover, the software claims that even if there are crossing hair strands, they are correctly identified (black rectangle)
Article Snippet: The recorded photographs were loaded into the
Techniques: Software
Journal: International Journal of Trichology
Article Title: Automated Digital Image Analysis (TrichoScan®) for Human Hair Growth Analysis: Ease versus Errors
doi: 10.4103/0974-7753.66905
Figure Lengend Snippet: Poor correlation between clinical thinning of hair and TrichoScan analysis of vellus hair percentage. (a) Clinical picture of a male patient with vertex thinning. Star depicting the target area for TrichoScan analysis. (b) TrichoScan analysis of the image taken from the patient in . Red circle highlights the vellus hair percentage reading of 18.4%
Article Snippet: The recorded photographs were loaded into the
Techniques:
Journal: International Journal of Trichology
Article Title: Automated Digital Image Analysis (TrichoScan®) for Human Hair Growth Analysis: Ease versus Errors
doi: 10.4103/0974-7753.66905
Figure Lengend Snippet: Error in hair detection as it emerges from the scalp (internal scalp fragments of hair). (a) Day 3 image of a patient; (b) magnification of the encircled portion of showing a single strand emerging from the scalp at the scalp ostium (white arrow). (c) TrichoScan analysis of the image in ; (d) magnification of the encircled portion of showing that the software falsely fragments the single hair strand into two at the point of exit from the scalp surface (white arrow) as a telogen hair (red) beneath the surface of the scalp and an anagen hair (green) above the surface
Article Snippet: The recorded photographs were loaded into the
Techniques: Software
Journal: International Journal of Trichology
Article Title: Automated Digital Image Analysis (TrichoScan®) for Human Hair Growth Analysis: Ease versus Errors
doi: 10.4103/0974-7753.66905
Figure Lengend Snippet: Repetition of errors in hair detection within the same image. (a) Day 3 image of a patient. Yellow arrows mark the points of exit of the hair strands from the scalp ostia. (b) TrichoScan analysis of the image in . Black arrows depict repeated points of exit from the scalp surface where the software falsely analyzed the strand beneath the surface of the scalp as a separate telogen strand
Article Snippet: The recorded photographs were loaded into the
Techniques: Software
Journal: International Journal of Trichology
Article Title: Automated Digital Image Analysis (TrichoScan®) for Human Hair Growth Analysis: Ease versus Errors
doi: 10.4103/0974-7753.66905
Figure Lengend Snippet: Hair strands crossing each other. (a) Close-up of two hair strands (red arrows) crossing each other. (b) TrichoScan analysis of the hair in . The software fragments the two hair strands at the point of crossing (purple cross) into four strands (arrows): two telogen (red) and two anagen (green)
Article Snippet: The recorded photographs were loaded into the
Techniques: Software
Journal: International Journal of Trichology
Article Title: Automated Digital Image Analysis (TrichoScan®) for Human Hair Growth Analysis: Ease versus Errors
doi: 10.4103/0974-7753.66905
Figure Lengend Snippet: Erroneous fragmentation of hair strands. (a) Close-up of two hair strands (red arrows) emerging from a single ostium (black circle) on the scalp surface. (b) TrichoScan analysis of the hair in . The software falsely fragments the two hair strands into multiple hair (white arrows). These errors are most probably due to the fact that the hair strands in emerge from the same ostium and are in close approximation to each other. Also, the hair strand thickness is not uniform throughout its length
Article Snippet: The recorded photographs were loaded into the
Techniques: Software